Communique on physical security 2024-002
RCMP approved combination locks operation aide-mémoire
On this page
The purpose of this aide-mémoire is to assist authorized individuals in operating RCMP-approved combination locks.
Note: The combination used in this aide-mémoire is for demonstration purposes only
S&G 8500 Series Safe Dials
Note: Prior to step 1, it is recommended to spin the dial 4-5 times to clear the mechanism
If the combination is 87-24-59, you would:
- Spin the dial to the left (counter clockwise) passing 87 three times and stop on 87 on the 4th turn.
- Spin the dial to the right (clockwise) passing 24 two times and stop on 24 on the 3rd turn.
- Spin the dial to the left (counter clockwise) passing 56 one time and stop on 56 on the 2nd turn.
- Spin the dial to the right (clockwise) stop on 0 (do not pass it). Push in on the dial and let it spring back out. Spin the dial right (clockwise) until the dial locks (usually around 85).
- Pull on the drawer/handle to open the drawer/door.
S&G 8400 Series Safe Dials
Note: Prior to step 1, it is recommended to spin the dial 4-5 times to clear the mechanism
If the combination is 87-24-59, you would:
- Spin the dial to the left (counter clockwise) passing 87 three times and stop on 87 on the 4th turn.
- Spin the dial to the right (clockwise) passing 24 two times then stop on 24 on the 3rd turn.
- Spin the dial to the left (counter clockwise) passing 59 one time then stop on 59 on the 2nd turn.
- Spin the dial to the right (clockwise) stop on 0 (do not pass it). Hold the dial at 0 with one hand and turn the centre lever on the dial to the right with the other hand. Spin the dial right (clockwise) until the dial locks (usually around 85).
- Pull on the drawer/handle to open the drawer/door.
S&G 6700 Series Safe Dials
Note: Prior to step 1, it is recommended to spin the dial 4-5 times to clear the mechanism
If the combination is 87-24-59, you would:
- Spin the dial to the left (counter clockwise) passing 87 three times and stop on 87 on the 4th turn.
- Spin the dial to the right (clockwise) passing 24 two times then stop on 24 on the 3rd turn.
- Spin the dial to the left (counter clockwise) passing 59 one time then stop on 59 on the 2nd turn.
- Spin the dial to the right (clockwise) until the dial stops.
- Pull on the drawer/handle to open the drawer/door.
S&G 2937 Series Safe Dials
Note: Prior to step 1, it is recommended to spin the dial 4-5 times to clear the mechanism
If the combination is 87-24-59, you would:
- Spin the dial to the left (counter clockwise) passing 87 three times and stop on 87 on the 4th turn.
- Spin the dial to the right (clockwise) passing 24 two times then stop on 24 on the 3rd turn.
- Spin the dial to the left (counter clockwise) passing 59 one time then stop on 59 on the 2nd turn.
- Spin the dial to the right (clockwise) stop on 0 (do not pass it). Push in on the dial and let it spring back out. Spin the dial right (clockwise) until the dial locks (usually around 85).
- Pull on the drawer/handle to open the drawer/door.
S&G 8077 Series High Security Combination Padlock
Note: Prior to step 1, it is recommended to spin the dial 4-5 times to clear the mechanism
If the combination is 87-24-59, you would:
- Spin the dial to the left (counter clockwise) passing 87 three times and stop on 87 on the 4th turn.
- Spin the dial to the right (clockwise) passing 24 two times then stop on 24 on the 3rd turn.
- Spin the dial to the left (counter clockwise) passing 59 one time then stop on 59 on the 2nd turn.
- Spin the dial to the right (clockwise) stop on 0 (do not pass it).
- Pull down on the body of the lock to release the shackle.
Contact us
Contact the RCMP LSA with your Physical Security inquiries at RCMP LSA Org Email: rcmp.lsa-grc.posm@rcmp-grc.gc.ca or visit the RCMP LSA web page.
- Date modified: